Chengdu Mechan Electronic Technology Co., Ltd

Chengdu Mechan Electronic Technology Co., Ltd Manufacture and leader of bipolar Plasma Surgery System (generator and instruments) for ENT / Orthopedic / Urology / Ophthalmology.

Manufacturer from China
Verified Supplier
7 Years
Home / Products / Plasma Surgery System /

PLA -700 Snoring Treatment Plasma Surgery System Minimally Invasive Ablation

Contact Now
Chengdu Mechan Electronic Technology Co., Ltd
Visit Website
City:chengdu
Province/State:sichuan
Country/Region:china
Contact Person:Townie
Contact Now

PLA -700 Snoring Treatment Plasma Surgery System Minimally Invasive Ablation

Ask Latest Price
Video Channel
Brand Name :Mechan
Model Number :PLA-700
Certification :CE,ISO
Place of Origin :CHINA
MOQ :5sets
Price :Negotiable
Payment Terms :L/C, T/T
Supply Ability :100000 set per month
Delivery Time :1-3weeks
Packaging Details :Cartons
Mode :Ablation, Placoag
Origin :China
Feature :Bipolar
Warranty time :1 Year
Type :ENT
Spare parts :Pedal, Probes,Saline Controller
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Snoring Treatment Plasma Surgery System Minimally Invasive Ablation

Trouble-shooting

The PLA-700 includes automatic self-diagnostics. If the diagnostics detect an error, the system sounds an audible tone, and deactivates the unit output power.

Most errors result from faults in accessories (like treatment handle/probe, footswitch) attached to the unit. The following table lists the issues, describes the errors, and recommends actions to take to resolve the errors.

If the unit displays any other error, it requires service.

Fuse Replacement

Fuses for the unit reside directly below the Power Cable Receptacle on the rear of the unit.

To replace the fuses, follow this procedure:

  1. Unplug the power cord from the wall outlet.
  2. Remove the power cord form the Power Cable Receptacle on the rear panel.
  3. To release the fuse drawer, insert a small flathead screwdriver into the slot on the drawer below the power cord receptacle. Then, slide the drawer out.
  4. Remove the two fuses and replace them with new fuses with the same values/specifications refer to section 7 system specification.
  5. Insert the fuse holder into the Power Cable Receptacle.

Periodic inspection

Every six months, visually inspect the PLA-700 for signs of wear or damage.

In particular, look for any of the following problems:

  • Damage to the power cord
  • Damage to the power cable receptacle
  • Obvious damage to the unit
  • Damage to any receptacle
  • Accumulation of lint or debris in or around the unit.

PLA -700 Snoring Treatment Plasma Surgery System Minimally Invasive Ablation